Location : M2 (West Tai Wo - Free Field)  
Day time 07:00-19:00 hrs Normal Weekdays Impact Noise Monitoring Results  
 
  Measured Noise Level for 30-min, dB(A) Limit Level, dB(A) Exceedance (Y/N)
Date Start Time Leq* L10* L90*
4-Mar-14 14:30 68.7 70.0 66.6 75 N
10-Mar-14 14:50 64.9 68.3 61.2 75 N
21-Mar-14 14:00 67.9 69.6 64.3 75 N
27-Mar-14 14:30 67.2 69.6 64.5 75 N
Location : M3 (Fanling Government Secondary School- Façade)
Day time 07:00-19:00 hrs Normal Weekdays Impact Noise Monitoring Results  
 
  Measured Noise Level for 30-min, dB(A) Limit Level, dB(A)^ Exceedance (Y/N)
Date Start Time Leq L10 L90
4-Mar-14 13:40 62.9 64.0 59.0 70 N
10-Mar-14 14:00 69.6 72.4 66.5 70 N
21-Mar-14 13:05 64.1 66.0 60.0 70 N
27-Mar-14 13:35 63.6 64.9 60.0 70 N
 
*  +3dB(A) Façade effect correction included  
^ Limit Level of 70dB(A) applies to education institutes while 65dB(A) applies during school examination period.