Location : M2 (West Tai Wo - Free Field)
Day time 07:00-19:00 hrs Normal Weekdays Impact Noise Monitoring Results
  Measured Noise Level for 30-min, dB(A) Limit Level, dB(A) Exceedance (Y/N)
Date Start Time Leq* L10* L90*
15-Dec-14 10:08 68.8 71.3 65.0 75 N 7585775.75 13489628.83 3162277.66
Location : M3 (Fanling Government Secondary School- Façade)
Day time 07:00-19:00 hrs Normal Weekdays Impact Noise Monitoring Results
  Measured Noise Level for 30-min, dB(A) Limit Level, dB(A)^ Exceedance (Y/N)
Date Start Time Leq L10 L90
15-Dec-14 11:21 64.5 66.7 61.3 70 N 2818382.931 4677351.413 1348962.883
*  +3dB(A) Façade effect correction included