Location : SR77 (Yuen Leng 2 - Free Field)
Day time 07:00-19:00 hrs Normal Weekdays Impact Noise Monitoring Results
Date Start Time End Time Measured Noise Level (dB(A))* Baseline Corrected Level, dB(A)** Baseline Noise Level Limit Level Exceedance
 L10(30min)  L90(30min)  Leq(30min)  (dB(A)), Leq(30min) dB(A) (Y / N)
3/10/2017 Sunny 11:30 74.5 61.5 70.5 - 67.8 75.0 N
9/10/2017 Cloudy 11:30 89.0 64.5 73.0 - 67.8 75.0 N
19/10/2017 Fine 11:30 93.5 62.0 73.5 - 67.8 75.0 N
25/10/2017 Sunny 11:30 92.5 59.5 73.5 - 67.8 75.0 N
31/10/2017 Sunny 11:30 93.0 59.0 74.0 - 67.8 75.0 N
Remarks
*  +3dB(A) Façade effect correction included
** Baseline corrected level is only calculated when measured noise level (Leq) > limit level.